Xantrex TrueCharge2 10A Battery Charger
2 banks, 110/220V Input, 12v Output
Model: 804-1210
UPC: 687873007741
- Microprocessor-controlled, multistage charging algorithms
- Charges flooded, gel, AGM or lead-calcium batteries
- Auto-ranging universal input voltage (90-265 Vac, 47-63 Hz) is also compatible with a generator or other low-quality power sources
- Power factor corrected, temperature-compensated charging
- Ability to charge healthy batteries drained to low voltage
- Mounting is possible in a variety of orientations and in areas where space is limited
- Easy access to AC and DC wiring from one side
- Tested to conform to ingress protection rating IP32 and meets UL1564, UL1236 including marine supplement and ABYC standards
- Reverse battery polarity protection
- Drip-proof design
- Over temperature protection
- DC over-voltage protection
- Battery overcharging protection
The new TRUECHARGE2 10-amp charger replaces the former best-selling, first-generation TRUECHARGE 10TB unit and features universal auto ranging input voltage (90 Vac to 265 Vac, 47 to 63 Hz), which can be used in most parts of the world. The TRUECHARGE2 10-amp is smaller and lighter than its predecessor and can be mounted in a variety of positions.
The TRUECHARGE2 10-amp charger uses power factor correction to deliver a full three-stage charge cycle. As a result, the charger requires less incoming AC power to operate at its peak efficiency, freeing up more usable AC power for onboard electronics. The TREUCHARGE2 10-amp charger meets stringent safety and regulatory standards including UL1564 and UL1236.
Regulatory Compliance
CSA E60335-2-29, UL1564, and UL1236 including the Marine Supplement and drip test. CE Marked for the Low Voltage Directive (safety) and the EMC Directive. Complies with IEC 60335-2-29 including Australian deviations. Ingress protection rating IP32 per EN/IEC 60529. Complies with FCC Part 15B and Industry Canada ICES-003 Class B emissions limits. Complies with ABYC A-31
Specifications
Electrical Specifications | |
Output current (nominal) | 10A |
Output voltage (nominal, depending on settings) | |
Charge | 14.2 – 15.5 Vdc |
Float | 13.4 – 13.8 Vdc |
Equalize | NA |
DC Output connections | 2 |
AC input coltage | 90-265 Vac 47-63 Hz 120 Vac, 230 Vac, 240 Vac nominal |
Temperature compensation | 3 settings |
Charger efficiency | > 80% |
Battery Type | Gel, Flooded, AGM, Pb-Ca |
Minimum recommended battery bank size | 20ah |
General Specifications | |
Operating Temperature | 0 to 65°C |
Storage temperature | -40 to 80°C |
Battery connection | Two positive terminals One negative terminal |
Dimensions | 2.7 x 5.4 x 8.8 |
WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov.